INFINITY
Residential Elevator
®
Roped Hydraulic Residential Elevator
Planning Guide
ASME A17.1 - 2000 Part 5 Section 5.3
CAN/CSA B44 - 2000 Part 5 Section 5.3
Effective April 1, 2004
ELEVATORS and LIFTS
®
Vista de página 0
1 2 3 4 5 6 ... 11 12

Resumo do Conteúdo

Página 1 - INFINITY

INFINITYResidential Elevator®Roped Hydraulic Residential Elevator Planning GuideASME A17.1 - 2000 Part 5 Section 5.3CAN/CSA B44 - 2000 Part 5 Section

Página 2

Wood Construction Sectional ViewINFINITYResidential ElevatorWood Construction Plan View Rail BracketCPG-INFVER01 © 2004, Concord Elevator Inc.Page 10

Página 3

Masonry Construction Elevation ViewBLOCK WALL (8" MINIMUM)(See Note 1)INFINITYResidential ElevatorMasonry Construction Plan View Rail BracketNote

Página 4

INFINITYResidential ElevatorDrawing Notes1 See Elevator Drawing for rail bracket spacing and pit depth.2 Wall lateral support spacing:- for 2" x

Página 5

INFINITYResidential ElevatorIntroductionThis planning guide is designed to assist architects, contractors, home owners and elevator professionals in p

Página 6

Equipment for Residential ElevatorINFINITYResidential ElevatorThis elevator meets the requirements of ASME A17.1 Part 5, Section 5.3 and CAN/CSA B44 P

Página 7

Hoistway and Cab ConfigurationsINFINITYResidential ElevatorChoice of Five VariationsImportant Note: Finished hoistway dimensions must include the dryw

Página 8

Elevator Guide RailsHydraulic Lifting Cylinder3/8" Wire Rope CableElevator CabCab Operating PanelCab GateOverheadDiagram of Elevator ShaftPitHois

Página 9

INFINITYResidential ElevatorSpecifications for Part 5.3 CompliancePART 1 - GENERALSCOPETo furnish all labor, materials and equipment necessary or requ

Página 10

INFINITYResidential ElevatorSpecifications for Part 5.3 ComplianceContinuedPART 4 – PRODUCT DATA4.1 MANUFACTURER/PRODUCTThe elevator shall be the CONC

Página 11

INFINITYResidential ElevatorSpecifications for Part 5.3 ComplianceContinued4.15.3Guides shall be bolted through the hoistway enclosure with back-up pl

Página 12 - 1-800-661-5112

Suggested Support Wall Wood ConstructionNote: The drawings on this page are for reference only. Building structural engineer to ensure that the buildi